What should we pay attention to when use the RF Isolators/circulators?
Time : 2022-02-18

1. Please note the direction of isolator and circulator is very important.
The reverse operation is not allowed, which would cause the malfunction or damage eventually.

2. It is required to use non-inductive stainless screws, and make sure the parts are well grounded.

3. RF Isolators and circulators have magnetic property, please keep away from ferromagnetic substances during operation.
For example, the cabinet box materials like iron, stainless etc. are not recommended which may affect the tuning of components.

4. When the wattage is relatively high, the heat dissipation structure is a must.

5. The layout gap is also an attentive point. It varies by types and frequency band. Please consult our technique by actual situation.